Growatt 3600MTL |
Growatt 4200MTL |
Growatt 5000MTL |
| Input Data |
| Max. DC power |
3800W |
4400W |
5200W |
| Max. DC voltage |
600V |
600V |
600V |
| PV voltage range MPPT |
120V - 550V |
120V - 550V |
120V - 550V |
| Max. number of parallel strings |
2/2 |
2/2 |
2/2 |
| Number of MPP trackers |
2(can parallel) |
2(can parallel) |
2(can parallel) |
| Max. DC power each MPPT |
2000W |
2500W |
3000W |
| Max. input current of each MPP tracker |
10A / 10A |
15A / 15A |
15A / 15A |
| Output (AC) |
| Nominal AC output power |
3600W |
4200W |
4600W/5000W * |
| Max. output current |
15.6A |
18.5A |
20A |
| Nominal AC voltage range |
220V/230V/240V 180V - 280V |
220V/230V/240V 180V - 280V |
220V/230V/240V 180V - 280V |
| AC grid frequency range |
50Hz, 60Hz / ‡ 5Hz |
50Hz, 60Hz / ‡ 5Hz |
50Hz, 60Hz / ‡ 5Hz |
| Phase shift (cos φ) |
1 |
1 |
1 |
| THDI |
<3% |
<3% |
<3% |
| AC connection |
Single phase |
Single phase |
Single phase |
| Efficiency |
| Max.efficiency |
97.6% |
97.9% |
97.9% |
| Euro-eta |
94% |
94.7% |
94.7% |
| MPPT efficiency |
99.5% |
99.5% |
99.5% |
| Protection Devices |
| DC reverse polarity protection |
yes |
yes |
yes |
| AC short-circuit protection |
yes |
yes |
yes |
| Ground fault monitoring |
yes |
yes |
yes |
| Grid monitoring |
yes |
yes |
yes |
| Integrated all-pole sensitive leakage current monitoring unit |
yes |
yes |
yes |
| General Data |
| Dimensions (W / D / H) in mm |
360/510/188 |
360/510/188 |
360/510/188 |
| Weight |
24KG |
24KG |
24KG |
| Operating temperature range |
-25 °C ... +60 °C |
-25 °C ... +60 °C |
-25 °C ... +60 °C |
| Noise emission (typical) |
≤25 dB(A) |
≤25 dB(A) |
≤25 dB(A) |
| Consumption: operating (standby)/ night |
< 5W / < 0.5 W |
< 5W / < 0.5 W |
< 5W / < 0.5 W |
| Topology |
transformerless |
transformerless |
transformerless |
| Cooling concept |
No fan |
No fan |
No fan |
| Installation: Indoors / Outdoors (IP65 ) |
yes / yes |
yes / yes |
yes / yes |
| Altitude |
Up to 2000m without power derating |
Up to 2000m without power derating |
Up to 2000m without power derating |
| Humidity |
0 ~ 95%, no condensation |
0 ~ 95%, no condensation |
0 ~ 95%, no condensation |
| Features |
| DC connection:(MC3/MC4/H4) |
opt /opt / yes |
opt /opt / yes |
opt /opt / yes |
| AC connection: Terminals |
yes |
yes |
yes |
| LCD display |
yes |
yes |
yes |
| Interfaces: Bluetooth/RS485/RS232 |
opt /opt / yes |
opt /opt / yes |
opt /opt / yes |
| Warranty: 5 years / 10 years |
yes / opt |
yes / opt |
yes / opt |
| Certificates and Approvals |
VDE0126-1-1, IEC62109,RD1663,G83
EN6100-6-1, EN6100-6-2, EN6100-6-3, EN6100-6-4
AS4777,AS/NZS3100 |